![Sinovo SD95H Series Manual Download Page 26](http://html1.mh-extra.com/html/sinovo/sd95h-series/sd95h-series_manual_1283225026.webp)
26
Function
Code
Name
Default
Property
Setting
Range
Group F05 Input Terminals
0
◎
0: No
function
1: Forward
rotation operation
2: Reverse rotation operation
3: 3-line running control
4: Forward jogging
5: Reverse jogging
6: Coast to
stop
7: Fault reset
8: Operation pause
9: External fault input
10: Increasing frequency setting (UP)
11: Decreasing frequency setting(DOWN)
12: Frequency increase or decrease
setting clear
13: Shift between A setting and B setting
14: Shift between c
ombination
setting and A setting
15: Shift between c
ombination
setting and B setting
16: Multi-stage speed
terminal 1
17: Multi-stage speed
terminal 2
18: Multi-stage speed
terminal 3
19: Multi-stage speed
terminal 4
20: Multi-stage speed
pause
21: ACC/DEC time selection 1
22: ACC/DEC time selection 2
23~24: Reserve
25: PID control pause
26~29: Reserve
30:
ACC
/
DEC prohibited
31~32: Reserve
33:Frequency
setting clear
34: DC
braking
35: General Motro/
High-frequency
Motor swith
36: Shift the command to the keypad
37: Shift the command to the terminal
38: Shift the command to the
communication
1
◎
4
◎
7
◎
0
◎
F05.00
F05.01
F05.02
F05.03
S2 terminal
function selection
S3 terminal
function selection
S1 terminal
function selection
F05.04
S4 terminal
function selection
Function Parameters Table
0: High pulse input
( see F05.24 ~ F05.28)
1: Digital inputs ( see F05.06)
HDI input
selection
0
◎
F05.05
S5 terminal
function selection
F05.06
0
HDI terminal
function selection
◎