![Sinovo SD95H Series Manual Download Page 29](http://html1.mh-extra.com/html/sinovo/sd95h-series/sd95h-series_manual_1283225029.webp)
29
Function
Code
Name
Default
Property
Setting
Range
Group F06
Output Terminals
●
0
0
0: Invalid
1: Running
2: Forward
running
3: Reverse
running
4: Jog
running
5: AC drive
fault
6: Frequency level detection
FDT1
7: Frequency
level
detection
FDT2
8: Frequency reached
9: Zero
-
speed
running
10: Upper
limit
frequency
reached
11: Lower limit
frequency
reached
12: Ready
for
running
13: Reserve
14:
Overload pre-alarming
15: Underload per-alarming
16~19: Reserve
20: External fault is valid
21: Reserve
22: Running
time
reached
23: MODBUS
communication
virtual terminal output
24: Reserve
F06.00
Reserve
●
0
Reserve
F06.04
○
1
Relay RO output
selection
F06.03
●
0
F06.02
Reserve
○
1
F06.01
Y output
selection
0x0
0.000s
0.000s
0.000s
○
○
○
○
0x0
~
0x3
Bit3 Bit2 Bit1 Bit0
0 0 Y RO
0.000~50.000s
0.000~50.000s
0.000~50.000s
Polarity of
output terminals
Y switch-on delay
time
Y switch-off delay
time
Relay RO switch-
on delay time
F06.05
F06.06
F06.07
F06.08
Function Parameters Table
○
Relay RO switch-
off delay time
F06.09
0.000s
0.000~50.000s