35
Function
Code
Default
Property
Setting
Range
Name
200.0~1000.0V
F08.27
Keypad digital
control setting
○
○
●
◎
○
○
○
F08.25
F08.23
F08.24
Energy
braking enable
Threshold
voltage of
energy braking
0: Energy braking disable
1: Energy braking enable
220V level:
380.0V
380V level:
700.0V
1
0
Reserve
0
F08.26
Over commission
selection
0: Over commission is invalid
1: Over commission is valid
1
0x0001
0x000~0x1221
LED ones: frequency control selection
0:
∧/∨
key adjustment is invalid
1:
∧/∨
key adjustment is valid
LED tens: frequency control
0: Only valid for F00.05=0 or
F00.06=0 setting
1: Valid for all frequency modes
2: Invalid for MS when MS is priority
LED hundreds: stop action selection
0: Setting is valid
1: Valid during running, cleared after
stopping
2: Valid during running, cleared after
receiving the stop command
LED thousands:
∧/∨
key integral
function
0: Integral function is valid
1: Integral function is invalid
F08.28
Integral ratio of
the keypad /
∧
∨
0.01~10.00s
0.10s
F08.29
UP/DOWN
terminal
control
setting
0x000
0x000~0x221
LED ones: frequency
control
0: UP/DOWN
terminal
setting valid
1: UP/DOWN
terminal
setting
invalid
LED tens: frequency
control
0: Only valid for F00.05=0 or
F00.06=0 setting
1: Valid for all frequency modes
2: Invalid for multi-sted when
multi-sted is priority
LED hundreds:
Action selection when stop
0: Setting is valid
Function Parameters Table