20
Function Parameters Table
Group F00 Basic Function
◎
Function
Code
Name
Default
Property
Setting
Range
○
◎
◎
0.0 Hz
50 Hz
◎
50 Hz
○
○
0: V/F
control
1: Vector mode 0 control
0: Keypad running command
channel (LED OFF)
1: Terminal running command channel
(LED ON )
2: MODBUS communication running
command channel (LED FLASH )
1
0: Keypad digital setting
1: Panel potentiometer setting
2: Analog AI1 setting
3: Reserve
4: High-pulse setting(HDI)
5: Simple PLC program setting
6: Multi-stage speed running setting
7: PID control setting
8: MODBUS communication setting
0.00Hz~F00.03 (Upper limit)
F00.04~600.00 Hz
F00.04~F00.02 (Max. frequency)
2
3
0
Speed
control mode
F00.00
Run
command
channel
F00.01
A frequency
command
selection
Lower limit of the
running frequency
Maximum output
frequency
Upper limit of the
running frequency
B frequency
command
selection
B frequency source
gain coefficient
B frequency
command
reference
0: Max output frequency
1: A frequency command
0
◎
0.0~100.0%
100.0%
○
F00.02
F00.03
F00.04
F00.05
F00.06
F00.07
F00.08
Combination mode
of the setting
0
○
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
F00.09