U-MATCH AIR CONDITIONERS INSTALLATION
73
Figure 1-3-16
2 OUTDOOR UNIT INSTALLATION
2.1 Before Installation
When the unit arrives, please check if any damage due to transport is existent. If any hurt is
found on the surface or inside, please declare to the transport company or the manufacturer in
writing.
Upon receipt of the unit, the unit and accessories shall be checked in accordance with the
packing list. Before acceptance, it must be confirmed that the model is correct and the unit is
in good shape and specification and quantity of accessories are right.
Correct handling route and method shall be decided to prevent damage to the unit. For
protecting the unit and ensuring its safety, carrying the unit with its package is recommended.
If such carrying method is difficult under particular conditions, the canton shall not be
removed to avoid looseness or falling during handling.
Confirm the foundation is secure. When the unit is installed on the metal part of a building,
electrical insulation must be in compliance with relevant standards.
Confirm the installation position is away from storage zone of inflammable and explosive
substances, or otherwise leakage of inflammable and explosive substances may lead to
explosion or a fire.
2.2 Installation Site
To ensure the unit in proper function, selection of installation location must be in accordance
with following principles:
Outdoor unit shall be installed so that the air discharged by outdoor unit will not r eturn and
that sufficient space for repair shall be provided around the unit.
The installation site must have good ventilation, so that the outdoor unit can take in and
exhaust enough air. Ensure that there is no obstacle for the air intake and exhaust of the
outdoor unit. If there is any obstacle blocking the air intake or exhaust, remove it.
Place of installation shall be strong enough to support the weight of outdoor unit, and it shall
be able to insulate noise and prevent vibration. Ensure that the wind and noise from the unit
will not affect your neighbors.
Avoid direct sunshine over the unit. It is better to set up a sun shield as the protection.
Summary of Contents for ASCU-12A
Page 1: ...SERVICE MANUAL INDOOR UNITS ASCU A ASDU A ASFU A UNI ON OFF SERIE OUTDOOR UNITS ASGE A ...
Page 2: ......
Page 3: ...1 PRODUCT ...
Page 24: ...U MATCH AIR CONDITIONERS PRODUCT 23 5 PIPING DIAGRAM ...
Page 25: ...24 CONTROL ...
Page 26: ...U MATCH AIR CONDITIONERS CONTROL 25 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation ...
Page 27: ...U MATCH AIR CONDITIONERS CONTROL 26 1 2 Heating Operation ...
Page 45: ...U MATCH AIR CONDITIONERS CONTROL 44 5 2 4 Dimensions ...
Page 48: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 47 INSTALLATION ...
Page 59: ......
Page 91: ...Model ASFU 60A ...
Page 93: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 91 MAINTENANCE ...
Page 160: ...PARTS GUIDE CASSETTE FLOOR CEILING DUCT UNITS OUTDOOR UNITS UNI ON OFF ...
Page 161: ......
Page 165: ...MAINTENANCE 162 2 Model ASGE 24A ASGE 24A WK Exploded Views ...
Page 167: ...MAINTENANCE 165 3 Model ASGE 36A Exploded Views ...
Page 169: ...ASGE 36A WK ...
Page 172: ...MAINTENANCE 168 4 Model ASGE 42A ASGE 42A WK Exploded Views ...
Page 174: ...MAINTENANCE 171 5 Model ASGE 48A ASGE 48A WK Exploded Views ...
Page 176: ...Model ASGE 60A WK ...
Page 187: ...U MATCH AIR CONDITIONERS MAINTENANCE 174 6 Model ASDU 60A Exploded Views ...
Page 191: ...MAINTENANCE 186 2 Model ASCU 24A ASCU 36A ASCU 42A ASCU 48A Exploded Views ...
Page 194: ...MAINTENANCE 189 5 2 3 Ceiling Type 1 Model ASFU 09A ASFU 12A ASFU 18A Exploded Views ...
Page 197: ...MAINTENANCE 192 2 Model ASFU 24A Exploded Views ...
Page 200: ...MAINTENANCE 195 3 Model ASFU 36A ASFU 42A ASFU 48A Exploded Views ...