![Sinclair ASCU-12A Service Manual Download Page 173](http://html.mh-extra.com/html/sinclair/ascu-12a/ascu-12a_service-manual_1280121173.webp)
No
Description
Part Code
Note
Qty
Price
Code
1
Front Grill
22414102
2
AL
2
Front Plate
01435436
1
BA
3
Protection Grill
01475432
1
AH
4
Top Cover
01255262
1
AQ
5
Back Side Plate
01305434
1
AR
6
Handle
26235253
3
AC
7
Valve Support
01715001
1
AH
8
Metal Base
01205433
1
AU
9
Front Side Plate
01305431
1
AT
10 Axial Flow Fan
10338731
2
AR
11 Condenser Assy
01125246
1
CL
12 Motor Support
01705431
1
AT
13 Motor FW68G
15013110
2
BC
14 Isolation Plate
01235440
1
AQ
15 Liquid-gas Support
07225011
1
BE
16 4-way Valve
43000338
1
AY
17 Compressor C-SBN373H8D
00129051
1
CN
18 Gas Valve
07130212
1
AQ
19 Liquid Valve
071302392
1
AG
20 Ambient Sensor (15K)
3900012126
1
AE
21 Temperature Sensor (20K)
3900012121
1
AD
22 Temperature Sensor (50K)
3900012129
1
AE
01395491
1
AH
01395737
WK
1
AH
24 Wire Clamp
71010102
1
AB
25 Terminal Board
42011044
1
AD
26 Terminal Board
42011103
2
AD
27 Terminal Board
420101851
1
AD
28 Capacitor CBB61 3.5
ȝ
F/450V
33010010
2
AG
29 AC Contactor GC3-18/01KK/3TF4211
44010226
1
AT
30
Overcurrent Protector HD-13.2-22/UO-10-
13
46020112
1
AS
31 Phase Reverse Protector
46020052
1
AX
32 Isolation Washer D
70410525
2
AC
33 4-way Valve Coil
430004002
1
AM
34 Compressor Gasket
0
35 Capillary Assy
04105242
1
AU
460200061
1
AL
46020007
1
AH
4602001519
WK
1
AL
37 Transformer 57X25D
43110240
1
AL
Main PCB WZ4C352
3022403301
without WK
1
BA
Main PCB WZ4C352
30224058
WK
1
BA
Main PCB ZS401D
30224211
WK
1
AZ
39 pressure switch
46020007
1
AH
MODEL: ASGE-42A, ASGE-42A WK
The data are subject to change without notice.
Electric Box
23
pressure switch
36
38
Summary of Contents for ASCU-12A
Page 1: ...SERVICE MANUAL INDOOR UNITS ASCU A ASDU A ASFU A UNI ON OFF SERIE OUTDOOR UNITS ASGE A ...
Page 2: ......
Page 3: ...1 PRODUCT ...
Page 24: ...U MATCH AIR CONDITIONERS PRODUCT 23 5 PIPING DIAGRAM ...
Page 25: ...24 CONTROL ...
Page 26: ...U MATCH AIR CONDITIONERS CONTROL 25 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation ...
Page 27: ...U MATCH AIR CONDITIONERS CONTROL 26 1 2 Heating Operation ...
Page 45: ...U MATCH AIR CONDITIONERS CONTROL 44 5 2 4 Dimensions ...
Page 48: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 47 INSTALLATION ...
Page 59: ......
Page 91: ...Model ASFU 60A ...
Page 93: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 91 MAINTENANCE ...
Page 160: ...PARTS GUIDE CASSETTE FLOOR CEILING DUCT UNITS OUTDOOR UNITS UNI ON OFF ...
Page 161: ......
Page 165: ...MAINTENANCE 162 2 Model ASGE 24A ASGE 24A WK Exploded Views ...
Page 167: ...MAINTENANCE 165 3 Model ASGE 36A Exploded Views ...
Page 169: ...ASGE 36A WK ...
Page 172: ...MAINTENANCE 168 4 Model ASGE 42A ASGE 42A WK Exploded Views ...
Page 174: ...MAINTENANCE 171 5 Model ASGE 48A ASGE 48A WK Exploded Views ...
Page 176: ...Model ASGE 60A WK ...
Page 187: ...U MATCH AIR CONDITIONERS MAINTENANCE 174 6 Model ASDU 60A Exploded Views ...
Page 191: ...MAINTENANCE 186 2 Model ASCU 24A ASCU 36A ASCU 42A ASCU 48A Exploded Views ...
Page 194: ...MAINTENANCE 189 5 2 3 Ceiling Type 1 Model ASFU 09A ASFU 12A ASFU 18A Exploded Views ...
Page 197: ...MAINTENANCE 192 2 Model ASFU 24A Exploded Views ...
Page 200: ...MAINTENANCE 195 3 Model ASFU 36A ASFU 42A ASFU 48A Exploded Views ...