![Sinclair ASCU-12A Service Manual Download Page 120](http://html.mh-extra.com/html/sinclair/ascu-12a/ascu-12a_service-manual_1280121120.webp)
U-MATCH AIR CONDITIONERS MAINTENANCE
119
3. Disassembly of 4-way
valve
●
Heat connection pipes for
4 pipes of 4-way valve
with gas welding before
removal of 4-way valve.
●
Record the direciton of the
4-way valve and
installation postition of
each pipe before welding
away 4-way valve.
4. Removal of 4-way valve
●
Remove the old 4-way
valve from the pipe line.
5. Assembly of new 4-way
valve
●
Position accurately the
new 4-way valve.
●
Connect new 4-way valve
with pipe line.
●
Wrap the valve with wet
cloth when welding 4-way
valve in case sliding block
inside the valve should be
burnt and water flow into
the pipe line.
●
Welding with nitrogen and
the nitrogen pressure shall
be 0.5±0.1kgf/c
㎡
(relative
pressure).
6. Assembly of solenoid
valve
●
Assemble solenoid valve
onto the new 4-way valve
in order of disassembly.
Disassemble
connecting
pipes at E,S,D
and C orifices
Mount a new
4-way vlave
Mount
solenoid
valve
Summary of Contents for ASCU-12A
Page 1: ...SERVICE MANUAL INDOOR UNITS ASCU A ASDU A ASFU A UNI ON OFF SERIE OUTDOOR UNITS ASGE A ...
Page 2: ......
Page 3: ...1 PRODUCT ...
Page 24: ...U MATCH AIR CONDITIONERS PRODUCT 23 5 PIPING DIAGRAM ...
Page 25: ...24 CONTROL ...
Page 26: ...U MATCH AIR CONDITIONERS CONTROL 25 CONTROL 1 OPERATION FLOWCHART 1 1 Cooling Dry Operation ...
Page 27: ...U MATCH AIR CONDITIONERS CONTROL 26 1 2 Heating Operation ...
Page 45: ...U MATCH AIR CONDITIONERS CONTROL 44 5 2 4 Dimensions ...
Page 48: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 47 INSTALLATION ...
Page 59: ......
Page 91: ...Model ASFU 60A ...
Page 93: ...GREE COMMERCIAL AIR CONDITION U MATCH AIR CONDITIONERS 91 MAINTENANCE ...
Page 160: ...PARTS GUIDE CASSETTE FLOOR CEILING DUCT UNITS OUTDOOR UNITS UNI ON OFF ...
Page 161: ......
Page 165: ...MAINTENANCE 162 2 Model ASGE 24A ASGE 24A WK Exploded Views ...
Page 167: ...MAINTENANCE 165 3 Model ASGE 36A Exploded Views ...
Page 169: ...ASGE 36A WK ...
Page 172: ...MAINTENANCE 168 4 Model ASGE 42A ASGE 42A WK Exploded Views ...
Page 174: ...MAINTENANCE 171 5 Model ASGE 48A ASGE 48A WK Exploded Views ...
Page 176: ...Model ASGE 60A WK ...
Page 187: ...U MATCH AIR CONDITIONERS MAINTENANCE 174 6 Model ASDU 60A Exploded Views ...
Page 191: ...MAINTENANCE 186 2 Model ASCU 24A ASCU 36A ASCU 42A ASCU 48A Exploded Views ...
Page 194: ...MAINTENANCE 189 5 2 3 Ceiling Type 1 Model ASFU 09A ASFU 12A ASFU 18A Exploded Views ...
Page 197: ...MAINTENANCE 192 2 Model ASFU 24A Exploded Views ...
Page 200: ...MAINTENANCE 195 3 Model ASFU 36A ASFU 42A ASFU 48A Exploded Views ...