Hz 2 Operator Wiring
Considerations / Installation
OPERATOR
WIRING CHART
MOTOR
CABLE
POWER
120VAC
BLACK
WHITE
GREEN
HOT
NEUTRAL
GROUND
BLACK
WHITE
GREEN
HOT
NEUTRAL
GROUND
POWER
120VAC 60Hz
1) FCC
-This device complies with part 15 of the FCC Rules. Operating is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
-Caution: Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
2) Hz Operator Wiring
All wiring must conform to the National Electrical Code and local codes
-The Hz operator can be wired to power in parallel (unlike normal AC tubular operators)
-
It is recommended that provisions be made to cut power individually when wiring Hz operators.
This can be in the form of an inline off/on switch, a disconnect plug, or access to the operator cable
for use of a installers power cable with off/on switch. The ability to cut the power to each motor
individually is required to easily program the receiver in the operator.
3) Installation
-The Hz motor uses standard T5 (not DMI) accessories.
-Use only SIMU accessories (brackets, adaptors, clips....)
-Mount Hz motor heads
at least
18 inches from each other to prevent RF interference.
-Always install the power cable with a drip loop to prevent water penetration
-SIMU motors conform to IP44 requirements and as such must be protected against direct weather
elements such as rain, sleet, ...etc.