MX575A/B DGPS Compass
52
Sentence Type - $PMVXG,303
Description:
Reset Control
This message allows the user to command various types of resets to the MX575.
Flow:
Input
$PMVXG,303
– Reset Control
Field
Description
Units
Format
Range
1
Reset Control
Int
0
= No Action
1
= Reset Serial I/O to
Factory Default Settings.
2
= Resets GPS
Parameters to Factory
Default settings, User I/O
Settings Remain
3
= Resets GPS
Parameters to Factory
Default Settings, I/O
Settings Return to
Factory Defaults.
4
= Reset All Parameters
Except the Oscillator
Model.
2
NULL
Example:
$PMVXG,303,3*57
$PMVXG,303,4*50