| 17
General information |
Argus Radar System Operator Manual
3
Technical specifications
Simplified conning infor-
mation
Graphic display of sensors, e.g.:
•
Wind sensor
•
Steering Gear
•
Heading sensor
•
CCTV Input
•
Echo sounder
•
SDME sensor
Additional PPI
Additional PPI with the same functions as the main PPI, including the possibility to interact
with different TXRXs at the same time
ECDIS interface
Function for complete integration with an ECDIS system connected via LAN
Video Combination
Possibility to select two radar sources and the possibility to view the two sources at the
same time in a single image. The automatic Tracking uses the two sources to track targets,
even across the blind sectors of the radar antennas
Data readout:
ARPA Target data
Range/bearing, speed/course, CPA/TCPA and Latitude/Longitude
AIS Target data
Ship Name, MMSI, Call Sign, Range/bearing, speed/course, CPA/TCPA and Latitude/Longi-
tude, Type, Status, Destination, ETA, ship size, AIS class
Ownship data
Heading, Speed/Course water or ground stabilized Geographic position and UTC time
System setting:
Safe Minimum CPA & TCPA, vector/past positions / trial / trials time
Alarms:
Acoustic and visual warning for: Dangerous Target, Target in Guard Zone, Lost Target, Sys-
tem Failure and external interface sensors (EPFS and AIS)
Other features:
Anchor-watch, echo reference speed (not for AIS enabled systems), EPFS speed
Built-in, electronic dual interswitch facility plus additional expansion, up to four transceivers.
Coaxial cable only connection (SXI mode) to TXRX
Inputs:
Gyro Heading
Analog: synchro or stepper. Digital Fast NMEA (IEC 61162-2)
Speed Log
Analog: PIT or two axis log. Digital: NMEA (IEC 61162-1)
EPFS
Serial Interface NMEA (IEC 61162-1)
AIS
Serial Interface NMEA (IEC 61162-1)
External Alarm Interface
Serial Interface NMEA (IEC 61162-1) – RAACK sentence
Outputs:
Serial Interface NMEA 0183 (IEC 61162-1)
RATTM - RAOSD – RARSD – RAALR – RATLB – RATTD sentences
Dead Man Alarm, Power Fail, Danger Target relay outputs configurable as NC or NO
Other interfaces:
Double Ethernet port 10/100 with a full set of TCP/IP protocols. System redundancy for LAN
connection failure
Four USB 2.0 port
Environmental features:
Operating temperature
-15°C / 55°C (IEC 60945 protected equipment)
Storage temperature
-25°C / 70°C (IEC 60945 protected equipment)
Relative humidity
Up to 95% at 40° (IEC 60945 protected equipment)
Water proofness
IP66
Vibrations
As per IEC60945
Power consumption:
500 W max (depending of monitor and wind load on TXRX)
Power Supply:
220/115 VAC 50/60 Hz
Dimensions:
Core unit only: Width 46 cm, height 35 cm, depth 15 cm
Weight:
Keyboard
2 kg
Core unit:
9 kg
Summary of Contents for ARGUS FMCW 3G
Page 1: ...ENGLISH ARGUSRADAR SYSTEM User Manual navico commercial com...
Page 2: ......
Page 149: ......
Page 150: ...988 10185 004...