130 |
Alert and system failures |
Argus Radar Operator Manual
Warning:
Note that it’s not possible to acknowledge a system failure or warning, the
only way to tur
n the fail LED off and remove the highlighting in the system status menu, is
t
o fix the failure.
Alert type
Icon
State
Indication
Alarm
Active -
not acknowledged,
not silenced
Flashing symbol and descriptive text.
Audible signal.
Active -
not acknowledged,
silenced
Flashing symbol and descriptive text.
No audible signal.
Active -
acknowledged
Steady symbol and descriptive text.
No audible signal.
Rectified -
not acknowledged
Flashing symbol and descriptive text.
No audible signal.
Warning
Active -
not acknowledged,
not silenced
Flashing symbol and descriptive text.
Audible signal.
Active -
not acknowledged,
silenced
Flashing symbol and descriptive text.
No audible signal.
Active -
acknowledged
Steady symbol and descriptive text.
No audible signal.
Active -
responsibility trans-
ferred
Flashing symbol and descriptive text.
No audible signal.
Rectified -
not acknowledged
Flashing symbol and descriptive text.
No audible signal.
Caution
Active
Steady symbol and descriptive text.
No audible signal.
Acknowledging alerts
To acknowledge an alert, you will first need to access the Alerts panel by moving the cursor
over the Alerts panel, and then press the left trackball button.
You select the alert you wish to acknowledge by hovering over the symbol for the alert and
press the left trackball button to acknowledge the alert.
If no active alerts or warnings are present, the softkey is labelled Alerts. Pressing this key
moves the cursor to the Alerts panel.
Press the cross button in the top right of the Alerts panel to exit the Alerts panel.
When an Alarm or Warning is acknowledged, the alert icon st
ops flashing and changes to the
acknowledged icon. The siren continues to sound if there are remaining unacknowledged
alarms or warnings, otherwise it is muted.
The acknowledged alert is then moved to its new position in the sort order.
All alerts remain in the Alerts panel until the reason for the alarm is rectified.