196
007-4498-002
C: System Controller Commands
pbay
The
pbay
set of commands displays information about the power bay, distributed power
supplies (DPSs), DC output ports, and FRUs:
•
pbay
•
pbay version
•
pbay dps
•
pbay dps
<dps number 1 - 6>
•
pbay dcport
•
pbay dcport
<DC port number 1 - 8>
•
pbay fru
•
pbay fru
<0 for power bay, 1 - 6 for DPS>
•
pbay reset
•
pbay env
•
pbay env on|off
•
pbay init
Use the
pbay
command to view the status of the power bay (refer to Example C-27).
Example C-27
pbay
Command Output
001r28-L1>pbay
Total current: 16.5 Amps (+/-11%)
Use the
pbay version
command to view the firmware version of the power bay (refer
Example C-28
pbay version
Command Output
001r28-L1>pbay version
PBay FW Version 00.18, Built 09/29/2001 14:00:00