![Silicon Graphics Origin 300 User Manual Download Page 113](http://html.mh-extra.com/html/silicon-graphics/origin-300/origin-300_user-manual_1271648113.webp)
Powering Your System On and Off
007-4498-002
87
Figure 3-26
PDU Circuit Breaker Switch
3. Set the power switch(es) of the TP900 storage module(s) to the On position.
4. Verify that all of the L1 controllers display “L1 running.” If any L1 controllers are
not running, contact your SGI system support engineer (SSE).
5. Press the power buttons that are located on the front of the modules that you want
to power on. Always power on the PCI expansion modules first. Next, power on the
NUMAlink module. Last, power on the Origin 300 base modules starting with the
global master (the lowest base module in the rack).
The power-button LEDs illuminate when the modules are powered on.
Power
distribution
unit (PDU)
Circuit breaker switch