Chassis Controller Interaction
007-5806-004
21
Note that the non-redundant example (shown in Figure 2-3) is a non-standard chassis management
configuration with only a single virtual local area network (VLAN) connect line from each CMC
to the internal LAN switch. See also “Multiple Chassis Manager Connections” in Chapter 3.
LAN1
LAN2
BMC
LAN1
LAN2
BMC
CMC-0
CMC-1
CMC-2
CMC-3
CMC-0
CMC-1
CMC-2
CMC-3
48-port
GigE switch
Rack 001 and 002 RLC
VLAN
Customer
LAN
System admin node
Service node
LAN1
LAN2
BMC
Rack 001
Rack 002
VLAN
Figure 2-3
Non-redundant Chassis Manager Interconnection Diagram Example
M-rack Chassis Manager Interconnection
The interconnection of an M-Cell’s rack environment is somewhat more complex than a D-rack
and requires the use of a third VLAN (VLAN3) within the Gigabit Ethernet switch network.
This VLAN3 interface allows the CMCs to monitor and adjust the activity of the cooling racks in
an M-cell as well as the external cooling distribution unit (CDU). The CDU rack supplies cooling
to the individual blades within the M-rack.
Figure 2-4 on page 22 shows a block diagram example of the interconnection scheme for an
M-Cell rack.
Summary of Contents for ICE X
Page 1: ...SGI ICE X System Hardware User Guide Document Number 007 5806 004 ...
Page 4: ......
Page 10: ......
Page 14: ......
Page 27: ...Powering the System On and Off 007 5806 004 7 Figure 1 5 Three Phase PDU Examples ...
Page 36: ......
Page 78: ...58 007 5806 004 4 Rack Information Figure 4 2 Front Lock on Tall 42U D Rack ...
Page 80: ...60 007 5806 004 4 Rack Information Figure 4 4 Air Cooled D Rack Rear Door and Lock Example ...
Page 84: ...64 007 5806 004 4 Rack Information Figure 4 6 SGI ICE X Multi Cell M Cell Rack Array Example ...
Page 86: ......