Using the 1U Console Option
007-5806-004
19
Using the 1U Console Option
The SGI optional 1U console is a rack-mountable unit that includes a built-in keyboard/touch-pad,
and uses a 17-inch (43-cm) LCD flat panel display of up to 1280 x 1024 pixels. The 1U console
attaches to the administrative controller server connectors or to an optional KVM switch (not
provided standard by SGI). The 1U console is basically a “dumb” VGA terminal, it cannot be used
as a workstation or loaded with any system administration program.
Note:
While the 1U console is normally plugged into the administrative controller server in the
SGI ICE X system, it can also be connected to a rack leader controller server in the system for
terminal access purposes.
The 27-pound (12.27-kg) console automatically goes into sleep mode when the cover is closed.
Levels of System and Chassis Control
The chassis management control network configuration of your ICE X series machine will depend
on the size of the system and the control options selected. Typically, any system with multiple
blade enclosures will be interconnected by the chassis managers in each blade enclosure.
Note:
Mass storage option enclosures are not monitored by the blade enclosure’s chassis manager.
Most optional mass storage enclosures have their own internal microcontrollers for monitoring
and controlling all elements of the disk array.
Chassis Controller Interaction
In all SGI ICE X series systems the system chassis management controllers communicate in the
following ways:
•
All blade enclosures within a system are polled for and provide information to the
administrative node and RLC through their chassis management controllers (CMCs). Note
that the CMCs are enlarged for clarity in Figure 2-3.
•
The CMC does the environmental management for each blade enclosure, as well as power
control, and provides an Ethernet network infrastructure for the management of the system.
Summary of Contents for ICE X
Page 1: ...SGI ICE X System Hardware User Guide Document Number 007 5806 004 ...
Page 4: ......
Page 10: ......
Page 14: ......
Page 27: ...Powering the System On and Off 007 5806 004 7 Figure 1 5 Three Phase PDU Examples ...
Page 36: ......
Page 78: ...58 007 5806 004 4 Rack Information Figure 4 2 Front Lock on Tall 42U D Rack ...
Page 80: ...60 007 5806 004 4 Rack Information Figure 4 4 Air Cooled D Rack Rear Door and Lock Example ...
Page 84: ...64 007 5806 004 4 Rack Information Figure 4 6 SGI ICE X Multi Cell M Cell Rack Array Example ...
Page 86: ......