Refrigerated Centrifuge Sigma 1-14K
6 Using the centrifuge
Version 05/2010, Rev. 2.12 of 15/08/2016 • sb
33 / 70
Translation of the original operating manual, part no. 0700102
Pos: 116 /10 0 Sigm a/10 0 BA Z entrif uge n Sigm a (Sta nda rd mod ule)/ 061 B etrie b_Spinc ont rol Basic/Spi ncon trol Ba sic /06 1-0 030 -00 30 St arte n ein er Zen trifu gatio n ( auß er 2-7 ) @ 27\ mod_ 140 532 034 929 6_6 8.doc x @ 1 937 95 @ 3 @ 1
6.3.3 Starting a centrifugation run
The centrifuge is ready for operation when the mains power switch is on
and the lid is closed.
• Press the start/stop key in order to start a centrifugation run.
Pos: 117 /01 0 Univ ersal mod ule/ Lee rzeile @ 0\ mo d_12 021 162 445 00_ 0.doc x @ 1 14 @ @ 1
Pos: 118 /10 0 Sigm a/10 0 BA Z entrif uge n Sigm a (Sta nda rd mod ule)/ 061 B etrie b_Spinc ont rol Basic/Spi ncon trol Ba sic /06 1-0 030 -00 40 U nter bre chen ein er Zent rifu gatio n @ 2 7\m od_ 140 532 0350 701 _68 .docx @ 1 9380 9 @ 3 @ 1
6.3.4 Interrupting a centrifugation run
• Press the start/stop key in order to interrupt a centrifugation run. The
centrifugation run will be terminated prematurely.
Pos: 119 /01 0 Univ ersal mod ule/ Lee rzeile @ 0\ mo d_12 021 162 445 00_ 0.doc x @ 1 14 @ @ 1
Pos: 120 /10 0 Sigm a/10 0 BA Z entrif uge n Sigm a (Sta nda rd mod ule)/ 061 B etrie b_Spinc ont rol Basic/Spi ncon trol Ba sic /06 1-0 030 -00 50 U nter bre chen ein es Bre msvo rga ngs @ 27\ mod _14 053 203 5218 7_6 8.d ocx @ 193 823 @ 3 @ 1
6.3.5 Interrupting a deceleration process
• Press the start/stop key during a deceleration process in order to
interrupt it and to restart the centrifuge.
Pos: 121 /01 0 Univ ersal mod ule/ Lee rzeile @ 0\ mo d_12 021 162 445 00_ 0.doc x @ 1 14 @ @ 1
Pos: 122 /10 0 Sigm a/10 0 BA Z entrif uge n Sigm a (Sta nda rd mod ule)/ 061 B etrie b_Spinc ont rol Basic/Spi ncon trol Ba sic /06 1-0 030 -00 60 D rehz ahl / R elative Ze ntrif ugal beschl euni gung (R ZB) @ 27\ mod_ 140 532 035 375 2_6 8.doc x @ 1 938 37 @ 3 @ 1
6.3.6 Speed / Relative centrifugal force (RCF)
The RCF value is determined by the rotor geometry and speed. The RCF
and speed values, therefore, depend on each other. If one of the two
values is entered, the other value will be set automatically.
• To preselect a speed value or a RCF value, press the set key
repeatedly until the corresponding unit flashes on the display.
• Select the desired speed or RCF value via the arrow keys.
• Confirm the selection by pressing the start/stop key.
The data will also be accepted and saved after approx. 20 seconds if no
other key is pressed within this time period.
During operation, you can switch from the speed value to the RCF value
and vice versa via the arrow keys.
Pos: 123 /01 0 Univ ersal mod ule/ Lee rzeile @ 0\ mo d_12 021 162 445 00_ 0.doc x @ 1 14 @ @ 1
Pos: 124 /10 0 Sigm a/10 0 BA Z entrif uge n Sigm a (Sta nda rd mod ule)/ 061 B etrie b_Spinc ont rol Basic/Spi ncon trol Ba sic /06 1-0 030 -00 60- 001 0 Änd ern des D rehz ahl- /RZB-W ertes wäh ren d de s La ufs @ 27\ mod _14 053 2035 524 4_6 8.do cx @ 1938 51 @ 4 @ 1
6.3.6.1 Changing the speed/RCF value during centrifugation
The preselected speed or RCF value can be changed during centrifugation.
• Press the set key repeatedly until the desired unit flashes on the
display.
• Change the speed or RCF value by pressing the arrow keys. The
parameters will take effect immediately.
Pos: 125 /01 0 Univ ersal mod ule/Seit enwec hsel @ 0\m od_ 120 211 624 4312 _0. docx @ 10 5 @ @ 1