Will not power up
▶
Verify the wiring per the instructions in the manual.
▶
Hold down the manual reset button for 15 second to force a “hard reboot”.
▶
Unplug the power cord for 60 seconds and restart.
▶
Call Sigalarm for remote assistance if available.
Frozen Screen
▶
Try adjusting the setpoint using the manual buttons. If the set point increases
or decreases the touchscreen is frozen, but not the control module. Power cycle
the unit to resolve the situation. Never touch the screen while the system is
powering up to avoid this problem.
▶
Hold down the manual reset button for 15 second to force a “hard reboot”.
Cannot adjust setpoint
▶
Verify that the lock setpoint feature in the admin screen is not selected.
▶
Verify that the max setpoint parameters in the admin screen are set in such
a way that allows adjustment.
SENSOR
No Data reading
▶
Check that the sensor is turned on.
▶
Verify that the battery is charged using test points on the board.
▶
The distance between the sensor and the control module maybe too great,
try repositioning.
Sensor reading is 0
▶
It is common to have a reading of zero, it is only a problem if the sensor is
near voltage.
▶
Test that the sensor is detection voltage by plugging in an extension cord and
moving it near the sensor, check that the reading increases.
▶
The voltage may be too low to detect at that distance.
▶
The powerline may be too far away for the sensor to detect at that voltage.