SIGALARM INSTALLATION AND OPERATION MANUAL /
GENERATION 4 WIRELESS
28
▶
If multiple lines are present the Sigalarm should be calibrated to the lowest
voltage line, and additional preventative measures may need to be utilized.
▶
The operator MUST fully understand how the Sigalarm is installed, operates, and
limitations before use.
▶
It is highly recommended that a Sigalarm distributor or an equally competent
person complete installations
▶
Prior to use operator training should be done by Sigalarm, it representatives, or a
competent person.
▶
When operating in close proximity to high voltage power lines vehicles should be
prohibited from traveling between the boom and power line.
▶
Adjust the Sigalarm setpoint when the boom angle and length is significantly
different than that used for the last setting.
▶
It is dangerous to operate any high lift vehicle beneath or above high voltage
lines
NO DATA
A no data status occurs when the sensor
is not transmitting data to the control
module for more than two seconds. This
means there is no protection zone around
the “down” sensor and the equipment
is no longer detecting voltage. Do not
operate equipment with a no data status.
The system will beep alerting the operator
of a no data status. See addition no data
notes in the trouble shooting section.
!
WARNING NOTES
GREATER THAN 10FT
Sigalarm systems should not be used on equipment operating closer
than 10 feet to a powerline