SIGALARM INSTALLATION AND OPERATION MANUAL /
GENERATION 4 WIRELESS
BELOW SET POINT
A below set point status occurs when all
of the sensors have a reading numerically
lower than the displayed set point. This
means the equipment is in the defined
work zone.
WARNING
A warning status occurs when one or more
sensors are within 80% of the set point.
This mean the equipment is getting closer
to but has not yet reached the danger
zone.
DANGER
A danger status occurs when one of the
sensor readings match the set point. This
means the equipment has crossed into the
danger zone. No set point adjustments can
be made during a danger status.
The Sigalarm system should be set to give a warning no closer than the minimum
approach distance or MAD from the power line. Set point adjustments can also
be made utilizing the increase or decrease buttons. Use a spotter to help you
determine a safe position while adjusting the setpoint.
!
SIGNIFICANT CHANGES IN BOOM LENGTH AND/OR ANGLE
MAY REQUIRE A SETPOINT ADJUSTMENT THAT DIFFERS
FROM THE INITIAL SETPOINT SELECTION AT SETUP.