SIGALARM INSTALLATION AND OPERATION MANUAL /
GENERATION 4 WIRELESS
22
ADMIN SCREEN FEATURES (ALL PASSWORD PROTECTED)
Set Point: Maximum set point parameters can be set to limit the operator’s ability
to increase the set point from the home screen. For example: if the admin selects
55 as the maximum set point, the operator can only increase the set point to 55
or less. This also limits the one touch feature to 55 or less.
Volume Max: The volume maximum can be set to limit the operator’s ability to
increase the volume of the external speaker. For example: vehicles working in
residential neighborhoods may require a softer alarm. This setting should never
bet set low enough that ground personnel cannot hear the external speaker. This
feature should always be set to the highest tolerable maximum.
Volume Min: The volume minimum can be set to limit the operator’s ability to
decrease the volume. A setting of 1 means the operator can adjust the volume of
the external speaker all the way down to silent. This is NEVER recommended. It is
imperative that ground personnel can hear the external speaker.
Lock Set Point: The lock set point feature can be selected to leave the operator
with no ability to increase or decrease the set point.
Disable Alarm Lockout: This feature will bypass normal relay continuity in
“danger” mode for emergency situations, similar to a manual override. When this
box is selected relay continuity will be configured as shown below. Proceed with
extreme caution when utilizing this feature.
Danger status with
“disable alarm lockout” selected
Red Black White
Relay Port 3 & 4
1
2
3
1
2
3
DISABLE ALARM LOCKOUT
Disable alarm lockout is only relevant if 2.0WRLY cable is installed & only
effects relay 3 & 4.