Allowed measuring range end values X2 (calibration factor Xc):
With single phase AC Active / Reactive / Apparent Power
[0.3
£
(X2 / Rated Power)
£
1.3 ]• (U • I /3)
N
N
With 3-phase AC Active / Reactive / Apparent Power
[0.3
£
(X2 / Rated Power)
£
1.3] • (3 • U • I )
N
N
(For single phase Rated Power =U • I /3 )
N
N
(For Three phase Rated Power = 3 • U • I )
N
N
° to Maximum Span 350°
Phase Angle & Power Factor measuring Range:
Minimum span 20
67
VA for one output
£
8
AC/DC Auxiliary Supply 60V…….300 VAC-DC ± 5%
24V…….60 VAC-DC ± 10%
Aux.Supply frequency range 45 to 65 Hz
Auxiliary Supply consumption
Auxiliary:
£
10VA for two outputs
60V…….300 VAC-DC
24V…….60 VAC-DC
VA for one output
£
5
£
6VA for two outputs