Engineer Programming Via the Keypad
50
Siemens Building Technologies
Fire Safety & Security Products
09.2008
10.3.5 Call ARC Mssg
To enable the Call ARC Message and to enter
details:
1.
Scroll to the CALL ARC MESSAGE
programming option.
2.
Press SELECT.
Î
The DISPLAY MESSAGE option displays.
3.
Press SELECT.
4.
Toggle between ENABLED and DISABLED for
preferred option.
5.
Press BACK and scroll to the next setting:
MESSAGE DETAIL 1.
6.
Press SELECT.
7.
Use the Keypad to enter the preferred
message detail.
8.
Press ENTER to save.
10.3.6 Keyfob
Restore
To enable or disable the Keyfob Restore feature:
1.
Scroll to the KEYFOB RESTORE
programming option.
2.
Press SELECT.
3.
Toggle between ENABLED and DISABLED for
preferred option.
4.
Press SAVE to update the setting.
10.3.7 User
Duress
To enable or disable the User Duress feature:
1.
Scroll to the USER DURESS programming
option.
2.
Press SELECT.
3.
Toggle between ENABLED and DISABLED for
preferred option.
4.
Press SAVE to update the setting.
10.3.8 Retrigger
To enable or disable the Retrigger feature:
1.
Scroll to the RETRIGGER programming option.
2.
Press SELECT.
3.
Toggle between ENABLED and DISABLED for
preferred option.
4.
Press SAVE to update the setting.
...CALL ARC MESSAGE...
BACK
SELECT
...ENABLED...
BACK
SAVE
DISPLAY MESSAGE
BACK
SELECT
CALL ARC
BACK ENTER
..MESSAGE DETAIL 1...
BACK
SELECT
..KEYFOB RESTORE..
BACK
SELECT
ENABLED
BACK
SAVE
...USER DURESS...
BACK
SELECT
ENABLED
BACK
SAVE
...RETRIGGER...
BACK
SELECT
ENABLED
BACK
SAVE