8
TECHNICAL DATA
76
SITRANS FX300
www.siemens.com/flow
06/2009 - SFIDK.PS.050.F2.02 A5E02100423
Flow rate limits
Product
Nominal sizes
Minimum flow rates
Maximum flow rates
EN
ASME
[m/s]
[ft/s]
[m/s]
[ft/s]
Liquids
DN15
…
300
½…
12"
0.5x(998/
ρ
)
0.5
1
1.64x(998/
ρ
)0.5
2
7x(998/
ρ
)
0.47
1
23x(998/
ρ
)0.47
2
Gas, steam
DN15
…
300
½…
12"
6x(1.29/
ρ
)
0.5
3
16.4x(1.29/
ρ
)0.5
4
7x(998/
ρ
)
0.47
3
23x(998/
ρ
)0.47
4
ρ
= operating density [kg/m
3
]
1
Minimum flow rate 0.3 m/s - maximum flow rate 7 m/s
2
Minimum flow rate 0.984 ft/s - maximum flow rate 23 ft/s
3
Minimum flow rate 2 m/s - maximum flow rate 80 m/s; DN15 up to 45 m/s and DN25 up to 70 m/s
4
Minimum flow rate 6.6 ft/s - maximum flow rate 262 ft/s; DN15 up to 148 ft/s and DN25 up to 230 ft/s