INSTALLATION
3
19
SITRANS FX300
www.siemens.com/flow
06/2009 - SFIDK.PS.050.F2.02 A5E02100423
3.4.1 Measurement of liquids
Prohibited installation
Prohibited installation
Prohibited installation
Prohibited installation
Figure 3-2: Upper pipe bend
CAUTION!
Prohibited: Installing the device in an upper pipe bend
1
, because there is a risk of gas bubbles
2
forming. Gas bubbles can lead to pressure surges and inaccurate measurement.
Figure 3-3: Downpipe and outlet
CAUTION!
Prohibited: Installing the device in a downstream pipe
3
or upstream pipe of a outlet
4
. There is
the risk of partially filled pipes.
MA_Siemens_Sitrans_FX300_R02_en_PRT.book Page 19 Monday, June 22, 2009 8:17 AM
Summary of Contents for SITRANS FX300
Page 1: ......
Page 79: ...NOTES 9 79 SITRANS FX300 www siemens com flow 06 2009 SFIDK PS 050 F2 02 A5E02100423 ...
Page 80: ......