6.5.6 Menu item Setup (firmware version - basic)
Level
Designation
Selection / entry
Explanation
3.1
Set display
3.1.1
Error Msg.
→
Display error
Yes
↑
...
Shows error messages in measuring mode in plain text
alternating with the measured values
No
↑
...
^
Flashing cursor in the top left corner of the display
indicates errors.
3.1.2
Cycle.Disp.
→
Display measured values
Yes
↑
...
Cyclically display measured values in measuring mode
(6 s intervals)
No
↑
...
^
Do not display measured values cyclically
3.1.3
Code 1
→
Set security query 1 (menu)
Yes
↑
...
Activate access code:
→→→↑↑↑
^^^
No
↑
...
^
Deactivate access code
3.2
I/O settings
3.2.1
4-20mA off
→
Current output 4-20 mA and error current
4-20mA
↑
...
Current output 4-20 mA
4-20/22E
↑
...
Current output 4-20 mA or error current 22 mA
4-20/3.55E
↑
...
^
Current output 4-20 mA or error current 3.55 mA
3.2.5
Function P
→
Pulse output
Yes
↑
...
Activate pulse output
No
↑
...
^
Deactivate pulse output
3.2.7
Totalizer
→
Totalizer
Tot. on
↑
...
Start totalizer
Tot. off
↑
...
^
Stop totalizer (value is held)
3.2.8
Tot. Conf.
→
Configure totalizer
(available if Maes.Inst =
Volume, see menu item
1.1.3)
m
3
Unit
↑
...
^
Select totalizer unit for volume flow measurement
0000000000
m
3
↑
…
↑
...
↑
...
^
Enter preset totalizer value
Reset yes /
Reset no
↑
...
^
Reset totalizer /
Do not reset totalizer/
Disp. off /
Disp. on
↑
...
^
Display totalizer /
Do not display totalizer
(available if Maes.Inst =
Norm. Vol., see menu
item 1.1.3)
m
3
norm
Unit
↑
...
^
Select totalizer unit for standard volume flow
measurement
0000000000
m
3
norm
↑
…
↑
...
↑
...
^
Enter preset totalizer value
Reset yes /
Reset no
↑
...
^
Reset totalizer /
Do not reset totalizer/
Disp. off /
Disp. on
↑
...
^
Display totalizer /
Do not display totalizer
MA_Siemens_Sitrans_FX300_R02_en_PRT.book Page 51 Monday, June 22, 2009 8:17 AM