MAG 8000 & MAG 8000 CT
43
SFIDK.PS.026.D9.02
Description
Specification
Meter
Accuracy MAG 8000
Standard calibration
± 0.4% of rate ± 2 mm/s
Extended calibration
± 0.2% of rate ± 2 mm/s
Accuracy MAG 8000 CT
Custody transfer
OIML R49 for DN 50 ... DN 300, Class 1 and 2 with turn down
up to Q3/Q1 = 400 at Q2/Q1 = 1.6
MI-001 verification for DN 50 ...DN 300, Class 2 with turn
down ratio Q3/Q1 = 80, Q3/Q1 = 63 or Q3/Q1 = 25 at Q2/Q1 = 6.3
Media conductivity
Clean water > 20
μ
s/cm
Temperature MAG 8000
Ambient
−
20 ... +60 °C (
−
4 ... +140 °F)
Media
0 ... 70 °C (32 ... +158 °F)
Storage
−
40 ... +70 °C (
−
22 ... +158 °F)
Temperature MAG 8000 CT
Ambient
−
20 ... +60 °C (
−
4 ... +140 °F)
Media
0.1 ... 30 °C (32 ... +70 °F)
Storage
−
40 ... +70 °C (
−
22 ... +158 °F)
Enclosure
IP68/NEMA 6P rating; Cable glands mounted requires Sylgard
potting kit to remain IP68/NEMA 6P, otherwise IP67/NEMA 4 rating
is obtained; Factory mounted cable provides IP68/NEMA 6P rating
Approvals MAG 8000
Drinking water approval
NSF 61 (cold water) USA
WRAS (BS 6920 cold water) UK
ACS Listed France
DVGW W270 Germany
Belaqua (B)
OIML R49 pattern approval
Approvals MAG 8000 CT
Drinking water approval
NSF 61 (cold water) USA
WRAS (BS 6920 cold water) UK
ACS Listed France
DVGW W270 Germany
Belaqua (B)
OIML R49 pattern approval
MI-001 approval
(Number: DK-0200-MI-001-002
or DK-0200-MI-001-004
)
Conformity
CEN EN 14154, ISO 4064
PED: 97/23EC
EMC: EN 61000-6-3, EN 61000-6-2, EN 61326-1
Sensor
Size, flange and pressure
range MAG 8000
EN 1092-1 (DIN 2501)
DN 25 and DN 40: PN 40
DN 50 … 150: PN 16
DN 200 … 600: PN 10 or PN 16
ANSI 16.5 Class 150 lb
1” … 2”: 580 psi
2” … 6”: 230 psi
8” … 24”: 145 or 230 psi
AS 4087
DN 50 … 600: PN 16
Size, flange and pressure
range MAG 8000 CT
EN 1092-1 (DIN 2501)
DN 50 … 300: PN 16
ANSI 16.5 Class 150 lb
2” … 12”: 230 psi
AS 4087
DN 50 … 300: PN 16
Max. excitation frequency
(Transmitter decide the selected
6.25 Hz for sensor size DN 25 ... 150 (1” ... 6”)
excitation frequency)
3.125 Hz for sensor size DN 200 … 600 (9” … 24”)
Liner
EPDM
Electrode and grounding
Hastelloy C276
electrodes
8.
Technical data
8.1 MAG 8000 & MAG
8000 CT
8. Technical data
Summary of Contents for SITRANS F M MAG 8000
Page 60: ...MAG 8000 MAG 8000 CT 60 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 61: ...MAG 8000 MAG 8000 CT 61 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 62: ...MAG 8000 MAG 8000 CT 62 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 63: ...MAG 8000 MAG 8000 CT 63 SFIDK PS 026 D9 02 10 Approvals and certificates ...