MAG 8000 & MAG 8000 CT
25
SFIDK.PS.026.D9.02
4. Commissioning
FT/PDM Meter
Display Parameter/data type
Factory settings
Data range
number
version view
Fix parameter or meter data that
not
are
changeable
570
All
-
Device Product ID
10779
600
All
-
Log interval
Monthly
Daily, Weekly (7 days), Monthly
601
All
-
Delay weekly log interval
0
0 to 30
602
All
-
Limit for too high consumption
1000000
-1*10^9 to 1*10*9
603
All
-
Limit for too low consumption
0
-1*10^9 to 1*10*9
610
All
L1
Date of latest log period
2000-01-01 T00:00
year-month-day T
hours:minutes:seconds
611
All
L1
Latest Log period totalized (1)
612
All
-
Latest Log period totalized (2)
613
All
-
Latest Log period fault status
0
Active faults in log period; 1: Insulation
error, 2: Coil current error, 3: Preamplifier
overload, 4: Database checksum error, 5:
Low power warning, 6: Flow overload war-
ning, 7: Pulse A overload warning, 8: Pulse
B overload warning, 9: Consumption inter-
val warning, 10/L: Leakage warning, 11/E:
Empty pipe warning, 12/C: Low impedance
/ high conductivity warning, 13/d: High flow
limit warning, 14/15/16: Not used
614
All
-
Latest Log period status
0
Meter operation conditions in log periode;
information
1: Totalizer 1 or 2 changed or reset, 2:
Tariff setting changed or reset, 3: Tariff
register changed or reset, 4: Date - time
changed, 5: Alarm active in logged period
(See alarm fault log for same period), 6:
Fault log has been reset, 7: HW lock
broken, 8: Power Up
615
All
L2
Date of log period 2
616
All
L2
Log period 2 totalized (1)
617
All
-
Log period 2 totalized (2)
618
All
-
Log period 2 fault status
See 168
619
All
-
Log period 2 status information
See 169
620
All
L3
Date of log period 3
621
All
L3
Log period 3 totalized (1)
622
All
-
Log period 3 totalized (2)
623
All
-
Log period 3 fault status
See 168
624
All
-
Log period 3 status information
See 169
625
All
L4
Date of log period 4
626
All
L4
Log period 4 totalized (1)
627
All
-
Log period 4 totalized (2)
628
All
-
Log period 4 fault status
See 168
629
All
-
Log period 4 status information
See 169
630
All
L5
Date of log period 5
631
All
L5
Log period 5 totalized (1)
632
All
-
Log period 5 totalized (2)
633
All
-
Log period 5 fault status
See 168
634
All
-
Log period 5 status information
See 169
635
All
L6
Date of log period 6
636
All
L6
Log period 6 totalized (1)
637
All
-
Log period 6 totalized (2)
638
All
-
Log period 6 fault status
See 168
639
All
-
Log period 6 status information
See 169
640
All
L7
Date of log period 7
641
All
L7
Log period 7 totalized (1)
642
All
-
Log period 7 totalized (2)
643
All
-
Log period 7 fault status
See 168
644
All
-
Log period 7 status information
See 169
645
All
L8
Date of log period 8
646
All
L8
Log period 8 totalized (1)
647
All
-
Log period 8 totalized (2)
648
All
-
Log period 8 fault status
See 168
649
All
-
Log period 8 status information
See 169
650
All
L9
Date of log period 9
651
All
L9
Log period 9 totalized (1)
Summary of Contents for SITRANS F M MAG 8000
Page 60: ...MAG 8000 MAG 8000 CT 60 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 61: ...MAG 8000 MAG 8000 CT 61 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 62: ...MAG 8000 MAG 8000 CT 62 SFIDK PS 026 D9 02 10 Approvals and certificates ...
Page 63: ...MAG 8000 MAG 8000 CT 63 SFIDK PS 026 D9 02 10 Approvals and certificates ...