Appendix
A.9 Information List
SIPROTEC, 7SJ61, Manual
C53000-G1140-C210-1, Release date 02.2008
420
273
Set Point Phase A dmd> (SP. I A
dmd>)
Set Points(MV)
OUT
On
Off
*
*
LED
BO
135
230
1
Yes
274
Set Point Phase B dmd> (SP. I B
dmd>)
Set Points(MV)
OUT
On
Off
*
*
LED
BO
135
234
1
Yes
275
Set Point Phase C dmd> (SP. I C
dmd>)
Set Points(MV)
OUT
On
Off
*
*
LED
BO
135
235
1
Yes
276
Set Point positive sequence
I1dmd> (SP. I1dmd>)
Set Points(MV)
OUT
On
Off
*
*
LED
BO
135
236
1
Yes
284
Set Point 37-1 Undercurrent
alarm (SP. 37-1 alarm)
Set Points(MV)
OUT
On
Off
*
*
LED
BO
135
244
1
Yes
301
Power System fault
(Pow.Sys.Flt.)
Device, General
OUT
On
Off
On
Off
135
231
2
Yes
302
Fault Event (Fault Event)
Device, General
OUT
*
on
135
232
2
Yes
303
sensitive Ground fault (sens Gnd
flt)
Device, General
OUT
On
Off
*
ON
135
233
1
Yes
320
Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
Device, General
OUT
On
Off
*
*
LED
BO
321
Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
Device, General
OUT
On
Off
*
*
LED
BO
322
Warn: Limit of Memory Operation
exceeded (Warn Mem. Oper.)
Device, General
OUT
On
Off
*
*
LED
BO
323
Warn: Limit of Memory New ex-
ceeded (Warn Mem. New)
Device, General
OUT
On
Off
*
*
LED
BO
356
>Manual close signal (>Manual
Close)
P.System Data 2
SP
*
*
*
LED BI
BO
150
6
1
Yes
395
>I MIN/MAX Buffer Reset (>I
MinMax Reset)
Min/Max meter
SP
on
*
*
LED BI
BO
396
>I1 MIN/MAX Buffer Reset (>I1
MiMaReset)
Min/Max meter
SP
on
*
*
LED BI
BO
403
>Idmd MIN/MAX Buffer Reset
(>Idmd MiMaReset)
Min/Max meter
SP
on
*
*
LED BI
BO
409
>BLOCK Op Counter (>BLOCK
Op Count)
Statistics
SP
On
Off
*
LED BI
BO
412
>Theta MIN/MAX Buffer Reset (>
Θ
MiMa Reset)
Min/Max meter
SP
on
*
*
LED BI
BO
501
Relay PICKUP (Relay PICKUP)
P.System Data 2
OUT
ON
m
LED
BO
150
151
2
Yes
502
Relay Drop Out (Relay Drop Out) Device, General
SP
*
*
510
General CLOSE of relay (Relay
CLOSE)
Device, General
SP
*
*
511
Relay GENERAL TRIP command
(Relay TRIP)
P.System Data 2
OUT
ON
m
LED
BO
150
161
2
Yes
533
Primary fault current Ia (Ia =)
P.System Data 2
VI
On
Off
150
177
4
No
534
Primary fault current Ib (Ib =)
P.System Data 2
VI
On
Off
150
178
4
No
535
Primary fault current Ic (Ic =)
P.System Data 2
VI
On
Off
150
179
4
No
545
Time from Pickup to drop out (PU
Time)
Device, General
VI
546
Time from Pickup to TRIP (TRIP
Time)
Device, General
VI
561
Manual close signal detected
(Man.Clos.Detect)
P.System Data 2
OUT
On
Off
*
*
LED
BO
916
Increment of active energy
(Wp
∆
=)
Energy
-
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
a
u
lt)
Log ON
/O
FF
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on