![Siemens SINAMICS V20 Series Operating Instructions Manual Download Page 89](http://html.mh-extra.com/html/siemens/sinamics-v20-series/sinamics-v20-series_operating-instructions-manual_378245089.webp)
Commissioning
5.6 Function commissioning
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
89
5.6.3.4
Running the inverter in economy mode
Functionality
Economy mode works by slightly changing the output voltage either up or down in order to
find the minimum input power.
NOTICE
The economy mode optimization is only active when operating at the requested frequency
setpoint. The optimization algorithm becomes active 5 seconds after the setpoint has been
reached, and is disabled on a setpoint change or if the I
max
or V
max
controller is active.
Typical applications
Motors with stable or slowly changing loads
Setting parameters
Parameter
Function
Setting
P1300[0...2]
Control mode
= 4: V/f Eco Mode with linear characteristic
= 7: V/f Eco Mode with quadratic characteristic
r1348
Economy mode factor [%]
This parameter displays the calculated economy mode factor
(range 80%-120%) applied to the demanded output voltage.
If this value is too low, the system may become unstable.
Function diagram
(&2OLQHDU
(&2TXDGUDWLF
(&2
IDFWRU
(&2
IDFWRU
9
9
I
I