Commissioning
5.5 Quick commissioning
SINAMICS V20 Inverter
Operating Instructions, 07/2012, A5E03728167
47
Parameter
Description
Factory
default
Default for
Cn005
Remarks
P0704[0]
Function of digital input 4
15
9
Fault acknowledgement
P1016[0]
Fixed frequency mode
1
1
Direct selection mode
P1020[0]
BI: Fixed frequency selection bit 0
722.3
722.1
DI2
P1021[0]
BI: Fixed frequency selection bit 1
722.4
722.2
DI3
P1001[0]
Fixed frequency 1
10
10
Fixed speed 1
P1002[0]
Fixed frequency 2
15
15
Fixed speed 2
P1074[0]
BI: Disable additional setpoint
0
1025.0
FF disables the additional setpoint
P0771[0]
CI: Analog output
21
21
Actual frequency
P0731[0]
BI: Function of digital output 1
52.3
52.2
Inverter running
P0732[0]
BI: Function of digital output 2
52.7
52.3
Inverter fault active
Connection macro Cn006 - External push button control
Note that the command sources are pulse signals.
OK
OK
M
M
10V AI 1 AI 2 0V DI 1 DI2 DI3 DI4 DIC 24V 0V
AO + AO- DO1+ DO1-
P+ N-
DO2
0V
0V
0~20mA=
0~50/60Hz
220V
N
2))KROG
21SXOVH
023XS
023GRZQ
)DXOW
5XQQLQJ
6SHHG
Connection macro settings:
Parameter
Description
Factory
default
Default for
Cn006
Remarks
P0700[0]
Selection of command source
1
2
Terminals as command source
P1000[0]
Selection of frequency
1
1
BOP MOP
P0701[0]
Function of digital input 1
0
2
OFF1 / hold
P0702[0]
Function of digital input 2
0
1
ON pulse
P0703[0]
Function of digital input 3
9
13
MOP up pulse
P0704[0]
Function of digital input 4
15
14
MOP down pulse
P0727[0]
Selection of 2 / 3-wire method
0
3
3-wire
ON pulse + OFF1 / HOLD +
Reverse
P0771[0]
CI: Analog output
21
21
Actual frequency
P0731[0]
BI: Function of digital output 1
52.3
52.2
Inverter running