Diagnosis and troubleshooting
03.99
6SE7087-6NX84-0GB0
Siemens AG
6-2
Operating Instructions
SIMOVERT MASTERDRIVES
During normal operation, the three CBL status LEDs (red, yellow and
green) light up synchronously and for the same length of time
(flashing)!
The stationary status of an LED (ON or OFF) indicates an unusual
operating status (parameterization phase or fault!)
During normal operation, the green CC-Link-LEDs are continuously lit.
The yellow one is off!
Diagnostic sequence:
❍
LED off
✹
LED flashing
●
LED continuous lit
-
LED information irrelevant
CBL status LEDs
CC-Link interface LEDs
Refer to
RED
YELLOW GREEN RDLED SDLED RUNLED ERRLED
❍
-
-
-
-
-
-
●
-
-
-
-
-
-
Case 1
✹
❍
❍
-
-
-
-
Case 2
✹
❍
●
-
-
-
-
Case 3
✹
●
❍
-
-
-
-
Case 4
✹
●
●
-
-
-
-
Case 5
✹
✹
❍
❍
-
-
-
Case 6
✹
✹
❍
●
❍
-
-
Case 7
✹
✹
❍
●
●
❍
-
Case 8
✹
✹
●
●
●
●
-
Case 9
-
-
-
-
-
-
✹
Case 10
✹
✹
✹
●
●
●
❍
o.k.
Table 6-3
Diagnostic sequence
NOTE
Diagnostic
sequence