Preparation for use
4.2 Transportation and storage
1PH1 main motors
Equipment Manual, 09/2021, A5E51077676A-AA
53
Long-term storage
If you intend to place the motor in storage for longer than six months, you must ensure that
the storage area satisfies the following contiditions.
Table 4- 1
Environmental conditions for long-term storage in the product packaging according to
Class 1K3 to EN 60721-3-1 - with the exception of influencing environmental variables
"Air temperature", "Highest relative humidity" and "Condensation"
Climatic ambient conditions
-15 °C to +55 °C
Highest relative humidity
< 60%, condensation not permissible
Mechanical ambient conditions
vibration-free storage room V
rms
< 0.2 mm/s
Protection against chemical sub-
stances
Protected in accordance with Class 1C2
Biological ambient conditions
Suitable in accordance with Class 1B2
Duration
•
Six months for the conditions listed above.
•
Special preservation measures are required for storage
period of six months up to two years.
Check the correct state of the motor every six months.
•
Check the motor for any damage.
•
Carry out any necessary maintenance work.
•
Document all preservation measures taken so that they can be reversed before the
machines are recommissioned.
•
Control the climate in the storage area if the conditions for storage cannot be complied
with.
•
Rotate the shaft extension by hand.
Condensation
The following ambient conditions encourage the formation of condensation:
•
Large fluctuations of the ambient temperature
•
Direct sunshine
•
High air humidity during storage
Avoid these ambient conditions.
Use a dehydrating agent in the packaging.
Summary of Contents for SIMOTICS M-1PH1
Page 1: ......
Page 2: ......
Page 8: ...Introduction 6 1PH1 main motors Equipment Manual 09 2021 A5E51077676A AA ...
Page 12: ...Table of contents 1PH1 main motors 10 Equipment Manual 09 2021 A5E51077676A AA ...
Page 133: ......
Page 134: ......