4.1 Motor components
SIMOTICS M-1FE2 built-in motors
54
Configuration Manual, 05/2021, A5E50494252B AB
4.1.1.4
Possible connections
NOTICE
Risk of damage to temperature-sensitive components
Some parts of the electrical motor enclosure can reach temperatures that exceed 100 °C. If
temperature-sensitive components, e.g. electric cables or electronic components, come into
contact with hot surfaces, these components could be damaged.
•
Carefully ensure that no temperature-sensitive components are in contact with hot
surfaces.
Connecting the Pt1000 temperature sensors
Note
Pt1000 temperature sensors are not ESD components.
Connect the Pt1000 temperature sensor independent of the polarity via two-conductor
yellow cables.
Note
Before you commission the motor, carefully check that the shutdown circuit via the PLC
(programmable logic controller) functions correctly.
You can connect the Pt1000 and PTC as follows:
•
PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 to SMC20 or SME20
•
PTC via thermistor motor protection 3RN2013-1GW30, Pt1000 directly connected to the
drive system
•
PTC and Pt1000 connected to SME120