Connecting
8.2 Electrical connection
SIMOTICS M-1FE2 built-in motors
114
Configuration Manual, 05/2021, A5E50494252B AB
Cable cross-sections (Cu) and outer diameter of the connecting cables
Motor type
Cable length l
l = 0.5 m
1)
l = 1.5 m
2)
Cable cross-section
per phase
in mm
2
Outer cable diame-
ter
in mm
Cable cross-section
per phase
in mm
2
Outer cable diame-
ter
in mm
8-pole built-in motors
1FE2093-8AG
☐☐
-
☐☐☐
1
3 x 4
3.9
3 x 4
3.9
1FE2093-8AM
☐☐
-
☐☐☐
2
6 x 4
3.9
6 x 4
3.9
1FE2094-8AJ
☐☐
-
☐☐☐
1
3 x 4
3.9
3 x 4
3.9
1FE2094-8AM
☐☐
-
☐☐☐
2
6 x 4
3.9
6 x 4
3.9
1FE2094-8CJ
☐☐
-
☐☐☐
1
3 x 6
5
3 x 6
5
1FE2094-8CG
☐☐
-
☐☐☐
2
6 x 4
3.9
6 x 4
3.9
1FE2095-8CJ
☐☐
-
☐☐☐
1
3 x 6
5
3 x 6
5
1FE2095-8CG
☐☐
-
☐☐☐
2
6 x 6
5
6 x 6
5
1FE2145-8CE
☐☐
-
☐☐☐
1
3 x 10
6.2
3 x 10
6.2
1FE2145-8CC
☐☐
-
☐☐☐
2
6 x 6
5
6 x 6
5
1FE2147-8CE
☐☐
-
☐☐☐
1
3 x 2 x 10
6.2
3 x 2 x 10
6.2
1FE2147-8CC
☐☐
-
☐☐☐
2
6 x 10
6.2
6 x 10
6.2
1)
According to EN 46200 it can only be used in the motor spindle
2)
Notes on using cables are provided in VDE 0298, Part 3 and Part 4
You configure further connection cables appropriate for the rated current in accordance with
EN 60204-1 depending on the routing type and the ambient temperature.