6.4 Fuses
Fuses in the armature circuit and in the motor circuit
Recommended Siemens semiconductor fuses (depending on the SIMOREG CCP used):
Unit Order No.
(MLFB)
Rated
current
Rated
voltage
Fuses
1U1, 1V1, 1W1
Fuses
1C1, 1D1
6RA7085-6FC00-0
600 A
460 V
3NE3335 (560 A / 1000 V)
3NE7431-0C (350 A / 2000 V)
6RA7091-6FC00-0
1200 A
460 V
3NE3335 (560 A / 1000 V)
3NE7431-0C (350 A / 2000 V)
6RA7090-6KC00-0
1000 A
690 V
3NE3335 (560 A / 1000 V)
3NE7431-0C (350 A / 2000 V)
6RA7095-6FC00-0
2000 A
460 V
3NE3338-8 (800 A / 800 V)
3NE7648-1C (525 A / 2000 V)
6RA7095-6KC00-0
2000 A
690 V
3NE3338-8 (800 A / 800 V)
3NE7648-1C (525 A / 2000 V)
Note
It is no longer recommended to use the fuse types as listed in previous editions of the SIMOREG
CCP operating instructions.
Fuses for pre-charging
10 A line protection e.g. type Diazed 5SD604
Fuses F1 and F2 in the Power Interface
Only UL-listed or UL-recognized fuses may be used in UL-listed units.
Wickmann 198 1 A / 250 V 5 x 20 mm time-lag
Wickmann 343 1 A / 250 V 6.3 x 32 mm time-lag
Schurter FSD 1 A / 250 V 5 x 20 mm time-lag order designation 0034.3987
Schurter FST 1 A / 250 V 5 x 20 mm time-lag order designation 0034.3117