![Siemens SIMOREG DC-MASTER Operating Instructions Manual Download Page 40](http://html.mh-extra.com/html/siemens/simoreg-dc-master/simoreg-dc-master_operating-instructions-manual_378158040.webp)
Connecting
12.2010
40
ENGLISH
Siemens AG 6RX1700-0DD74
SIMOREG DC-MASTER Converter Commutation Protector Operating Instructions
Connecting to a SIMOREG DC-MASTER:
56
57
58
59
60
56
57
58
59
60
X172
MINI-COMBICON
X172
MINI-COMBICON
Connecting to a SINAMICS DCM:
36
38
TX+
TX-
RX+
RX-
M
TX+
TX-
RX+
RX-
M
37
39
40
59
57
60
58
56
X-172
MINI COMBICON
SINAMICS DCM
SIMOREG CPP
X-177
Connector Board
Programming interface for the software update X300
Serial interface RS232
9-pin SUBMIN D socket
Module C98043-A7046 Power Interface SIMOREG CCP
Connector pin
X300
Function
2
Receive cable, RS232 standard (V.24)
5 Ground
7
Send cable, RS232 standard (V.24)
Cable:
1
2
3
4
5
9
8
7
6
1
2
3
4
5
9
8
7
6
PC COMx
socket
6RA70 X300
connector
X300
1
2 RxD (RS232)
3 Rx+/Tx+ (RS485)
4
5 Ground
6 +5V (OP1S)
7 Tx D (RS232)
8 Rx-/Tx- (RS485)
9 Ground
Use a shielded connecting cable. Ground the shield at both ends.
Additional connectors
Module C98043-A7046 Power Interface SIMOREG CCP
Connector Function
X165
"Output pulse inhibit": Used when connecting several SINAMICS DCM in parallel
X29_PAR
X30_PAR
Pulse turnoff interface to the parallel connection of SIMOREG CCPs
The two connectors are connected in parallel.