Appendix
A.4 Technology alarms
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
371
A.4.2
Technology alarms 101-110
Technology alarm 101
Alarm reaction: Remove enable
Restart: required
Alarm text
Solution
Error in the configuration
Faulty load gear factors.
Adjust the specified value.
Illegal value for the configuration data Actor.DriveParameter.MaxSpeed.
Adjust the specified value.
Illegal value for the configuration data DynamicLimits.MaxVelocity.
Adjust the specified value.
Illegal value for the configuration data maximum acceleration in Dynam-
icLimits.MaxAcceleration.
Adjust the specified value.
The set leadscrew pitch is invalid. Illegal value in Mechanics.Leadscrew
Adjust the specified value.
Illegal combination of data for homing with incremental encoder.
Adjust the specified value.
The set mounting position of the encoder is invalid. Illegal value in Sen-
sor.MountingMode.
Adjust the specified value.
The configuration of the measuring wheel circumference of the encoder is invalid.
Illegal value in Sensor.Parameter.DistancePerRevolution.
Adjust the specified value.
The configuration for the resolution of the linear encoder is faulty. Illegal value in
Sensor.Parameter.Resolution.
Adjust the specified value.
The set resolution of the encoder is invalid. Illegal value in Sen-
sor.Parameter.StepsPerRevolution.
Adjust the specified value.
The set fine resolution for Gn_XIST1 is invalid. Illegal value in Sen-
sor.Parameter.FineResolutionXist1.
Adjust the specified value.
The set fine resolution for Gn_XIST1 in Sensor.Parameter.FineResolutionXist1 is not
consistent with the setting in PROFIdrive parameter P979.
Adjust the specified value.
Illegal value for the configuration data Actor.Interface.Telegram.
Adjust the specified value.
The set encoder type is invalid. Illegal value in Sensor.Type.
Adjust the specified value.
The set encoder system is invalid. Invalid value in Sensor.System.
Adjust the specified value.
The set home position offset is invalid. Illegal value in Sen-
sor.ActiveHoming.HomePositionOffset.
Adjust the specified value.
Parameter of position monitoring faulty. Illegal value in PositioningMonitoring.Window. Adjust the specified value.
Parameter of position monitoring faulty. Illegal value in PositioningMonitoring.Window. Adjust the specified value.
The set home position offset is invalid. Illegal value in Sensor.ActiveHoming.Mode.
Adjust the specified value.
The set home position offset is invalid. Illegal value in Sensor.PassiveHoming.Mode. Adjust the specified value.
The configuration of the PROFIdrive interface of the actual value is faulty. Illegal
value in Sensor.Interface.Telegram.
Adjust the specified value.
Faulty controller factors.
Adjust the specified value.
Limit for standstill signal is faulty. Illegal value in StandStillSignal.VelocityThreshold.
Adjust the specified value.
Parameter of position monitoring faulty. Invalid value in PositioningMonitor-
ing.ToleranceTime.
Adjust the specified value.
Illegal value in Actor.Type.
Adjust the specified value.
Inconsistent PROFIBUS parameterization; the sum of Ti and To is greater than one
DP cycle clock.
Adjust the specified value.