Instructions
11.2 S7-1500 Motion Control V1
S7-1500 Motion Control V13 Update 3
288
Function Manual, 07/2014, A5E03879256-AC
Requirement
●
The technology object has been configured correctly.
●
"HomingMode" = 2, 3, 4, 5, 8
The technology object must be enabled.
●
"HomingMode" = 0, 1, 2, 6, 7
The encoder values must be valid. (<TO>.StatusSensor[n].State = 2)
Override response
●
An MC_Home job for passive homing is aborted by:
–
Disabling the technology object by means of "MC_Power.Enable" = FALSE
–
"MC_Home" job with parameter "HomingMode" = 4, 5, 9
●
An "MC_Home" job for passive homing does not abort any other Motion Control jobs.
●
An "MC_Home" job for active homing is aborted by:
–
Disabling the technology object with "MC_Power.Enable" = FALSE
–
"MC_Home" job "HomingMode" = 4, 5
–
"MC_Halt" job
–
"MC_MoveAbsolute" job
–
"MC_MoveRelative" job
–
"MC_MoveVelocity" job
–
"MC_MoveJog" job
●
An "MC_Home" job for active homing aborts the following running Motion Control jobs.
–
"MC_Home" job with parameter "HomingMode" = 2, 3, 4, 5
–
"MC_Halt" job
–
"MC_MoveAbsolute" job
–
"MC_MoveRelative" job
–
"MC_MoveVelocity" job
–
"MC_MoveJog" job