Instructions
11.1 S7-1500 Motion Control V2
S7-1500 Motion Control V13 Update 3
240
Function Manual, 07/2014, A5E03879256-AC
Requirement
●
The technology object has been configured correctly.
●
"Mode" = 2, 3, 5, 8, 10
The technology object must be enabled.
●
"Mode" = 0, 1, 6, 7, 8
The encoder values must be valid. (<TO>.StatusSensor[n].State = 2)
Override response
●
An MC_Home job for passive homing is aborted by:
–
Disabling the technology object by means of "MC_Power.Enable" = FALSE
–
"MC_Home" job with parameter "Mode" = 3, 5, 9
●
An "MC_Home" job for passive homing does not abort any other Motion Control jobs.
●
An "MC_Home" job for active homing is aborted by:
–
Disabling the technology object with "MC_Power.Enable" = FALSE
–
"MC_Home" job "Mode" = 3, 5
–
"MC_Halt" job
–
"MC_MoveAbsolute" job
–
"MC_MoveRelative" job
–
"MC_MoveVelocity" job
–
"MC_MoveJog" job
–
"MC_GearIn" job
●
An "MC_Home" job for active homing aborts the following running Motion Control jobs.
–
"MC_Home" job with parameter "Mode" = 3, 5, 8, 10
–
"MC_Halt" job
–
"MC_MoveAbsolute" job
–
"MC_MoveRelative" job
–
"MC_MoveVelocity" job
–
"MC_MoveJog" job
–
"MC_GearIn" job
–
"MC_MoveSuperimposed" job