S5-100U
Operations List, Machine Code and Abbreviations
*
1 RLO dependent ?
2 RLO affected ?
3 RLO reloaded ?
1)
RLO is set to “1”.
Conversion Operations
CFW
Form the one's complement of
ACCU 1.
CSW
Form the two's complement of
ACCU 1. CC 1/CC 0 and OV
are affected.
SRW
Shift the contents of ACCU 1
to the right by the value
specified in the parameter.
Unassigned positions are
padded with zeros.
CC 1/CC 0 are affected.
Shift Operations
SLW
Shift the contents of ACCU 1
to the left by the value
specified in the parameter.
Unassigned positions are
padded with zeros.
CC 1/CC 0 are affected.
Oper-
ation
(STL)
Permissible
Operands
RLO*
1
Function
2
3
Parameter
n=0 to 15
Parameter
n=0 to 15
N
N
N
N
N
N
N
N
N
N
N
N
JU=
N
Jump unconditionally to the
symbolic address.
N
N
Symbolic
address max.
4 characters
Jump Operations
JC=
Jump conditionally to the
symbolic address. (If the RLO
is “0”, it is set to “1”.)
Symbolic
address max.
4 characters
Y
1)
Y
Y
JZ=
Jump if the result is zero. The
jump is made only if CC 1=0
and CC 0=0. The RLO is not
changed.
JN=
Jump if the result is not zero.
The jump is made only if
CC 1 CC 0. The RLO is not
changed.
JP=
Jump if the sign of the result is
“+”. The jump is made only if
CC 1=1 and CC 0=0. The
RLO is not changed.
Symbolic
address max.
4 characters
Symbolic
address max.
4 characters
Symbolic
address max.
4 characters
N
N
N
N
N
N
N
N
N
JM=
JO=
Jump if the sign of the result is
“-”. The jump is made only if
CC 1=0 and CC 0=1. The
RLO is not changed.
Jump on overflow. The jump is
made only if the OVERFLOW
bit is set. The RLO is not
changed.
Symbolic
address max.
4 characters
Symbolic
address max.
4 characters
N
N
N
N
N
N
42
4
1.6
60
23
1.6
47+
n·10
12+
n·10
1.6
47+
n·10
12+
n·10
1.6
62
2
1.6
65
5
1.6
69
6
1.6
69
10
1.6
71
6
1.6
71
6
1.6
65
4
1.6
CPU 103
MA02 MA03
Execution Time
in
µ
s
CPU 100
CPU 102
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
EWA 4NEB 812 6120-02b
A-11
Summary of Contents for SIMATIC S5-100U
Page 6: ...EWA 4NEB 812 6120 02b ...
Page 16: ...EWA 4NEB 812 6120 02b ...
Page 21: ...1 The SIMATIC S5 System Family EWA 4NEB 812 6120 02b ...
Page 22: ...Figures 1 1 Members of the SIMATIC S5 System Family 1 1 EWA 4NEB 812 6120 02b ...
Page 23: ......
Page 27: ......
Page 36: ...EWA 4NEB 812 6120 02b ...
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 102: ...EWA 4NEB 812 6120 02b ...
Page 156: ...EWA 4NEB 812 6120 02b ...
Page 232: ...EWA 4NEB 812 6120 02b ...
Page 268: ...EWA 4NEB 812 6120 02b ...
Page 272: ...EWA 4NEB 812 6120 02b ...
Page 336: ...EWA 4NEB 812 6120 02b ...
Page 352: ...EWA 4NEB 812 6120 02b ...
Page 412: ...EWA 4NEB 812 6120 02b ...
Page 482: ...EWA 4NEB 812 6120 02b ...
Page 484: ...EWA 4NEB 812 6120 02b ...
Page 505: ...B Dimension Drawings EWA 4NEB 812 6120 02b ...
Page 515: ...C Active and Passive Faults in Automation Equipment EWA 4NEB 812 6120 02b ...
Page 516: ...EWA 4NEB 812 6120 02b ...
Page 522: ...EWA 4NEB 812 6120 02b ...
Page 523: ...D Information for Ordering Accessories EWA 4NEB 812 6120 02b ...
Page 524: ...EWA 4NEB 812 6120 02b ...
Page 530: ...EWA 4NEB 812 6120 02b ...
Page 531: ...E Reference Materials EWA 4NEB 812 6120 02b ...
Page 532: ...EWA 4NEB 812 6120 02b ...
Page 534: ...EWA 4NEB 812 6120 02b ...
Page 535: ...F Siemens Addresses Worldwide EWA 4NEB 812 6120 02b ...
Page 536: ...EWA 4NEB 812 6120 02b ...
Page 542: ...EWA 4NEB 812 6120 02b ...
Page 543: ...Index EWA 4NEB 812 6120 02b ...
Page 544: ...EWA 4NEB 812 6120 02b ...
Page 550: ...EWA 4NEB 812 6120 02b ...