The Integral Real-Time Clock
If your inputs differ from the ones described, the operating system outputs error messages that are
displayed in the status word. The operating system resets error messages displayed in the status
word the next time you set the clock, prompt time, or the operating hours counter, if the new
settings are within the definition range. See section 12.5.
If you do not wish to modify one of the setting values, you can enter at its place XX (ASCII code) in
DB1, or FF (hexadecimal code) when you are programming in the system data.
If the clock data area is located at the end of other areas (flags, data blocks, inputs, and outputs)
and there is insufficient memory space available for the clock data area, the amount of clock data
transferred is only as much as will fit in the area available. Settings are not accepted if they lie
outside of the available space.
•
If clock data is located in the non-retentive flag area, then the following two events occur:
- All the settings are lost after Power OFF and cold restart.
- The time the last switch from RUN to STOP occurred is lost.
•
Remember that you can decide where to locate the clock data area. The word numbers listed in
Table 12-3 are relative.
- If your clock data area is located in a data block and does not begin with data word DW0 but
DWX, then you must add the value X to the word number shown in Table 12-3.
Example:
Your clock data area begins with DW124. The data for the time and date is then
stored in DW124 to DW127.
- If you locate your clock data area in the flag area beginning with flag word 0, then you must
multiply the appropriate data word number listed in Table 12-3 by a factor of 2 to obtain the
appropriate flag word address.
Example:
You locate your clock data area in the flag operand area beginning with flag
word 0. Data for the operating hours counter is then stored beginning with the
FW24 address.
- If your clock data area does not begin at flag word 0, you have to add the beginning value to
the word number shown in Table 12-3.
EWA 4NEB 812 6120-02b
12-11
Summary of Contents for SIMATIC S5-100U
Page 6: ...EWA 4NEB 812 6120 02b ...
Page 16: ...EWA 4NEB 812 6120 02b ...
Page 21: ...1 The SIMATIC S5 System Family EWA 4NEB 812 6120 02b ...
Page 22: ...Figures 1 1 Members of the SIMATIC S5 System Family 1 1 EWA 4NEB 812 6120 02b ...
Page 23: ......
Page 27: ......
Page 36: ...EWA 4NEB 812 6120 02b ...
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 102: ...EWA 4NEB 812 6120 02b ...
Page 156: ...EWA 4NEB 812 6120 02b ...
Page 232: ...EWA 4NEB 812 6120 02b ...
Page 268: ...EWA 4NEB 812 6120 02b ...
Page 272: ...EWA 4NEB 812 6120 02b ...
Page 336: ...EWA 4NEB 812 6120 02b ...
Page 352: ...EWA 4NEB 812 6120 02b ...
Page 412: ...EWA 4NEB 812 6120 02b ...
Page 482: ...EWA 4NEB 812 6120 02b ...
Page 484: ...EWA 4NEB 812 6120 02b ...
Page 505: ...B Dimension Drawings EWA 4NEB 812 6120 02b ...
Page 515: ...C Active and Passive Faults in Automation Equipment EWA 4NEB 812 6120 02b ...
Page 516: ...EWA 4NEB 812 6120 02b ...
Page 522: ...EWA 4NEB 812 6120 02b ...
Page 523: ...D Information for Ordering Accessories EWA 4NEB 812 6120 02b ...
Page 524: ...EWA 4NEB 812 6120 02b ...
Page 530: ...EWA 4NEB 812 6120 02b ...
Page 531: ...E Reference Materials EWA 4NEB 812 6120 02b ...
Page 532: ...EWA 4NEB 812 6120 02b ...
Page 534: ...EWA 4NEB 812 6120 02b ...
Page 535: ...F Siemens Addresses Worldwide EWA 4NEB 812 6120 02b ...
Page 536: ...EWA 4NEB 812 6120 02b ...
Page 542: ...EWA 4NEB 812 6120 02b ...
Page 543: ...Index EWA 4NEB 812 6120 02b ...
Page 544: ...EWA 4NEB 812 6120 02b ...
Page 550: ...EWA 4NEB 812 6120 02b ...