![Siemens SIMATIC 627B Operating Instructions Manual Download Page 50](http://html.mh-extra.com/html/siemens/simatic-627b/simatic-627b_operating-instructions-manual_380750050.webp)
Commissioning
7.5 Notes on operation
SIMATIC Box PC 627B
48
Operating Instructions, 06/2008, A5E00927393-02
7.5.2
2HDD system (optional)
The two hard disks are configured as follows in the factory state of the device:
Hard disk 0
Hard disk 1
Partition C: System, NTFS, 20 GB
Partition D: Data, NTFS, remaining capacity
Not configured
The two hard disks are connected to the SATA ports 0 and 2. The hard disk on SATA port 2
is not configured. This gives you the option of backing up your data to this hard disk. For
information on hard disk capacities, refer to your order documentation.
Booting from the slave hard disk
The system boots by default from the hard disk on SATA port 0. You can also configure the
system to boot from the disk on SATA port 2.
In order to allow booting from the second hard disk, you need to configure it as the primary
boot device. Make the following settings in your BIOS Setup:
Select Boot > Hard Drive > <Drive name> e.g. FUJITSU MHT2060BH - SATA2, then press
the "+" key to move it up in the boot order.
NOTICE
The drive letters for the partitions on both drives are assigned by the operating system
used. You can change these in the Control Panel as required.