Description
3.7 Design
SIMATIC Box PC 627B
26
Operating Instructions, 06/2008, A5E00927393-02
3.7.4
Status displays
PROFINET status display
PROFINET status display
6)352),1(7
Display
Meaning
LED
Description
OFF
•
CP not available
•
CP disabled
•
No error, communication
established
•
Download in progress
Slow flashing
•
Link status error
•
IO controller: IO device cannot
be addressed
•
IO controller: Duplicate IP
address
Fast flashing
Exception error: Diagnostics via
Web or SNMP no longer possible
SF PROFINET
(optional)
Status display for CP
1616 onboard
AN
•
Diagnostic information
available
•
No communication
established.
Virtual status displays
The two "virtual" CP 1616 LEDs can only be seen in the SIMATIC software and can be scanned via
SNMP.
RUN
CP is active
STOP
CP is in the stop state
PROFINET
Virtual LEDs
Flashes
There are no "slow flashing" or
"fast flashing" states.