![Siemens SIMATIC 627B Operating Instructions Manual Download Page 194](http://html.mh-extra.com/html/siemens/simatic-627b/simatic-627b_operating-instructions-manual_380750194.webp)
Detailed descriptions
16.4 BIOS Setup
SIMATIC Box PC 627B
192
Operating Instructions, 06/2008, A5E00927393-02
Entry
Meaning
[Enabled]
Onboard monitoring functions are enabled.
[Disabled]
No monitoring functions.
SafeCard functions
The relevant driver and the application must be started for operation of the
monitoring functions.
[Enabled]
The fan speed is controlled based on the temperature.
Fan Control
[Disabled]
The fan always runs at full speed.
[Disabled]
Only one CRT or DVI monitor is driven.
Dual view DVI/CRT
[Enabled]
When a CRT and a DVI monitor are connected, both are
activated.
Auto
BIOS detects whether another graphics module is inserted and
switches over depending on the "Default Primary Video Adapter"
setting.
Onboard Graphics
(IGD)
Disabled
The integrated graphics is disabled in the chipset. This setting
should only be selected if another graphics card is installed.
* This menu item depends on the device features
Note
The second Ethernet interface support is OS dependent. For DOS based applications (e.g.
Image Creator) please use the first Ethernet interface.
Note
For or operation without a monitor (= headless operation), Dual view DVI/CRT should be set
to "Disabled".
Summary of Contents for SIMATIC 627B
Page 10: ...Table of contents SIMATIC Box PC 627B 8 Operating Instructions 06 2008 A5E00927393 02 ...
Page 30: ...Description 3 7 Design SIMATIC Box PC 627B 28 Operating Instructions 06 2008 A5E00927393 02 ...
Page 244: ...SIMATIC Industrial PC SIMATIC Box PC 627B Operating Instructions 06 2008 A5E00927393 02 242 ...