11
Operating status display
The current operating states of the AT12 are indicated by a suitable error state display
(Service Tool).
Display
Meaning
0
Reserve
1
RAM, EEPROM or CPU error (system error)
2
Brake chopper error
3
Error in the second shutdown route
4
Increased hold-open time with longer motor switch-on time
5
Motor undefined
6
Motor blocked in direction of closure
7
Incremental encoder error
8
Reserve
9
Motor overcurrent
A
Reserve
b
15 V overvoltage
c
Blockage while opening
C
Reserve
d
Door remains stationary during initialization run (no OPEN or CLOSE signal, or door
has reached end position)
E
Motor overvoltage
F
Motor undervoltage
h
15 V undervoltage
H
Parameter determination (learn run)
n
Output stage defective
L
Ammeter error
o
Function OK
P
Parameter error (error during learn run)
u
Door is closed
U
Maximum door weight exceeded
—
Controller waiting for learn run, door system has no valid parameter values
Elevator door drive AT12
Manual, 02/2012, A2B00086683A-04
33
Summary of Contents for SIDOOR AT12
Page 2: ......
Page 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Page 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Page 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Page 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Page 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Page 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Page 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Page 47: ......