Electric adjustment and commissioning
Elevator door drive AT12
Manual, 02/2012, A2B00086683A-04
25
12.
Once the controller has detected the door "OPEN" and "CLOSED" end positions, the
subsequent opening and closing movements proceed at normal speed once again.
Note
Door movements in the "OPEN" and "CLOSE" directions can also be actuated with the
learn run button S501.
13.
The door travel values can be matched to the individual door for specific applications.
This requires the Service Tool to be connected.
A PC, on which the Software Kit operating program has been started, can also be
connected via the USB adapter, which is available as a special accessory. Its operation is
described in the Appendix to these instructions.
The following settings can be made:
Function
Adjustment range
Factory setting
Creep distance Open
0... 100 mm
25 mm
Cutter distance Open
0... 100 mm
30 mm
Creep distance Close
0... 100 mm
20 mm
Cutter distance Close
0... 100 mm
40 mm
Maximum speed Open
100... 500 mm/s
500 mm/s
Creep speed Open
30... 90 mm/s
40 mm/s
Cutter speed Open
30... 90 mm/s
60 mm/s
Initial speed Open
30... 90 mm/s
90 mm/s
Maximum speed Close
100... 500 mm/s
250 mm/s
Creep speed Close
30... 90 mm/s
60 mm/s
Cutter speed Close
30... 90 mm/s
40 mm/s
Initial speed Close
30... 90 mm/s
90 mm/s
Nudge speed Close
50... 250 mm/s
150 mm/s
Acceleration ramp OPEN
300... 850 mm/s
2
850 mm/s
2
Braking ramp OPEN
300... 850 mm/s
2
600 mm/s
2
Reversing ramp OPEN/CLOSE
300... 850 mm/s
2
850 mm/s
2
Acceleration ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Braking ramp CLOSE
300... 850 mm/s
2
500 mm/s
2
Reversing ramp CLOSE/OPEN
300... 850 mm/s
2
850 mm/s
2
Continuous torque (power) OPEN
0... 1.5 A
1 A
Continuous torque (power) CLOSE
0... 1.5 A
1 A
Cutter press-on torque
0... 5.0 A
2.5 A
Opening force static
70... 120 N
120 N
Closing force static
70... 120 N
110 N
Cutter force static Close
70... 120 N
110 N
Nudge force static Close
70... 120 N
110 N
Summary of Contents for SIDOOR AT12
Page 2: ......
Page 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Page 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Page 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Page 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Page 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Page 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Page 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Page 47: ......