Electric adjustment and commissioning
WARNING
When electrical devices are used, certain parts of them have to carry dangerous voltages.
Failure to observe the operating instructions can therefore lead to serious injuries or
material damage.
It is essential to observe the warning notices.
The door movements cannot always be externally controlled while the controller is being
commissioned (in particular during the automatic determination of parameters).
Therefore an authorized person must be posted near the door to ensure that no one else
can come near the elevator door during commissioning.
After commissioning, the forces and energies in the entire elevator system must be
checked by the service personnel to ensure that they are within their permissible limits.
Note
The AT12 controller is powered via a direct plug-in connection to the 230 VAC mains supply.
The controller must be protected by a 6 A to 10 A (I²t > 30 A²/sec) fuse in the building. It is
essential to connect the PE to the X204 connector.
Note
The motor temperature must not be below 0°C during the parameter learn run, as otherwise
the weight of the door will be incorrectly determined, and the closing and nudge speeds may
lie in impermissible ranges.
Note
The
X101 control inputs plug is not plugged in during commissioning in order to prevent
uncontrolled movements.
1.
Push the door into the
"CLOSED" position.
2.
Plug in the
X801 motor plug.
3.
Plug in the
X204 power plug (supply voltage is switched off).
4.
Press and hold down the learn run button
(S501) .
5.
Switch on the supply voltage.
Elevator door drive AT12
Manual, 02/2012, A2B00086683A-04
23
Summary of Contents for SIDOOR AT12
Page 2: ......
Page 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Page 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Page 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Page 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Page 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Page 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Page 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Page 47: ......