Appendix
A.8 Diagnostics and parameterization
Elevator door drive AT12
44
Manual, 02/2012, A2B00086683A-04
A.8
Diagnostics and parameterization
The Service Tool and the Sidoor User Software can be used equally well for diagnostics and
setting the parameters
These tools are optionally available (see Appendix Order nos. of the individual parts
(Page 37)).
The Service Tool and the USB adapter for the Software Kit (Sidoor User Software) can be
connected to X102 on the controller with the associated cable.
The tool keys and buttons have identical inscriptions and functions.
Enter key, jumps to the next menu below
Escape key, jumps back to the menu above
Menu selection key, increases a parameter value
Menu selection key, decreases a parameter value
Parameters can be changed in the
"MAIN MENU QUICK ADJUSTMENT → Parameter
Setting" and in the "MAIN MENU TOTAL ADJUSTMENT → Profile Parameter" menus.
The desired parameter is selected with the
or the
key, and activated for the setting
with the Return key
(parameter value flashes).
The parameter value can then be increased or decreased by pressing the corresponding key
(see above).
The value is accepted by pressing the Return key again.
Summary of Contents for SIDOOR AT12
Page 2: ......
Page 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Page 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Page 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Page 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Page 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Page 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Page 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Page 47: ......