Electric adjustment and commissioning
Elevator door drive AT12
26
Manual, 02/2012, A2B00086683A-04
Parameters should always be adjusted during normal operation with the door in the
"CLOSED" position, because the controller then accepts the values immediately.
CAUTION
Taking the counterweights into account, the maximum static closing force must not exceed
150 N!
WARNING
Risk of injury through moving mechanical parts
After the elevator door has been commissioned, the permitted energies and forces on the
heaviest door in the entire (elevator) system must be checked by service personnel with
landing door and cabin door coupled, and adjusted if they exceed their limit values.
Gearing up or down is not allowed on the toothed belt because this would change the
kinetic energies or static forces on the door. The door width would then no longer be valid.
Note
After the optimal settings of the parameters have been determined, they can be noted in the
configuration record (see Appendix Settings record (Page 45)). This record should also be
kept at hand when asking questions on the Hotline.
Summary of Contents for SIDOOR AT12
Page 2: ......
Page 8: ...Introduction Elevator door drive AT12 8 Manual 02 2012 A2B00086683A 04 ...
Page 12: ...Definitions Elevator door drive AT12 12 Manual 02 2012 A2B00086683A 04 ...
Page 14: ...Overview of controls Elevator door drive AT12 14 Manual 02 2012 A2B00086683A 04 ...
Page 28: ...The relay contacts Elevator door drive AT12 28 Manual 02 2012 A2B00086683A 04 ...
Page 30: ...CAN Elevator door drive AT12 30 Manual 02 2012 A2B00086683A 04 ...
Page 32: ...Travel curve Elevator door drive AT12 32 Manual 02 2012 A2B00086683A 04 ...
Page 46: ...Appendix A 9 Settings record Elevator door drive AT12 46 Manual 02 2012 A2B00086683A 04 ...
Page 47: ......