Health and Safety Protection
Sicore II Installation and Commissioning Guide
667/HB/52600/000 Issue 2 Unrestricted
9
Health and Safety Protection
Safety IR IR Safety Warning
OPTICAL EMISSIONS OF THE SICORE II IR FLASH ARE IN EXCESS OF THE EXEMPT
GROUP, VIEWER-RELATED RISKS ARE DEPENDANT UPON HOW THE PRODUCT IS
INSTALLED AND USED
THIS PRODUCT IS CLASSIFIED AS RISK GROUP 1 AT A DISTANCE OF 298 mm
Safety of Installation and Maintenance Personnel
IT IS RECOMMENDED THAT DUE TO THE HAZARDS PRESENT WITHIN THE SICORE II CAMERA
THAT ALL POWER TO THE UNIT IS DISCONNECTED BEFORE WORKING ON THE UNIT. WHERE
A RISK ASSESSMENT AND METHOD STATEMENT FOR THE WORKS TO BE COMPLETED AND /
OR THE INSTRUCTIONS FOR THE OEM EQUIPMENT BEING INSTALLED OR REMOVED ALLOWS,
LIVE WORKING MAY BE CONSIDERED.
Safety of Maintenance Personnel
In the interests of health and safety, when using or servicing this equipment the following
instructions must be noted and adhered to:
Only skilled or instructed personnel with relevant technical knowledge and experience,
who are also familiar with the safety procedures required when dealing with modern
electrical/electronic equipment are to be allowed to use and/or work on the equipment.
All work shall be performed in accordance with the Electricity at Work Regulations 1989
or the relevant local, state and government regulations.
Such personnel must take heed of all relevant notes, cautions and warnings in this
Handbook and any other Document or Handbook associated with the equipment
including, but not restricted to, the following:
The equipment must be correctly connected to the specified incoming power supply.
The equipment must be disconnected / isolated from the incoming power supply before
removing any protective covers or working on any part from which the protective covers
have been removed.
Any power tools must be regularly inspected and tested.
Any ladders used must be inspected before use to ensure they are sound and not damaged.